Auriga AU-5
Introducing Auriga’s 5th generation pulsed IV/RF characterization system delivers unparalleled performance, capturing measurements with incredible speed and accuracy. Pulsed IV (current-voltage) measurements have emerged as the preferred method of capturing current-voltage characteristics of active devices such as field effect (FETs) and bipolar junction (BJTs) transistors. With the growing popularity of higher-power devices, like GaN HEMTs, LDMOS, SiC, and graphene, current and voltage requirements are constantly being pushed higher and higher.
View our list of High Power Bias Tee’s to compliment your Pulsed Test System.
Select a voltage so we can find the right system for you!
- Tab Title
- 220 V
- 600 V
- 1200 V
- 2000 V
Auriga PIV System - 220 V Configuration
Auriga’s 5th generation pulsed IV/RF characterization system delivers unparalleled performance, capturing measurements with incredible speed and accuracy. Pulsed
IV (current-voltage) measurements have emerged as the preferred method of capturing current-voltage characteristics of active devices such as field effect (FETs) and bipolar junction (BJTs) transistors. With the growing popularity of higher-power devices, like GaN HEMTs, LDMOS, SiC, and graphene, current and voltage requirements are constantly being pushed higher and higher.
Auriga MEM™, Auriga’s newest pulsed IV function, enhances current resolution to an industry-leading 0.01% of maximum current. Using Auriga’s advanced calibration algorithms and an external Keysight digital multimeter (DMM), Auriga MEM brings the DC measurement plane directly to the device under test.
Auriga 220V configuration
wdt_ID | Model | Description |
---|---|---|
1 | AU5 | Pulsed IV/RF Characterization System |
2 | PHG20 | Pulser Head, ±20 V, 100 mA, 2 W |
3 | PHD220-10 | Pulser Head, 220 V, 10 A, 200 W |
4 | N5751A | Power Supply to support 200 V Pulser Heads |
5 | AU5-RF (Optional) | Pulsed RF Option |
If you would like to customize your system further, Email us at info@focus-microwaves.com
Auriga PIV System - 600 V Configuration
Auriga’s 5th generation pulsed IV/RF characterization system delivers unparalleled performance, capturing measurements with incredible speed and accuracy. Pulsed
IV (current-voltage) measurements have emerged as the preferred method of capturing current-voltage characteristics of active devices such as field effect (FETs) and bipolar junction (BJTs) transistors. With the growing popularity of higher-power devices, like GaN HEMTs, LDMOS, SiC, and graphene, current and voltage requirements are constantly being pushed higher and higher.
Auriga MEM™, Auriga’s newest pulsed IV function, enhances current resolution to an industry-leading 0.01% of maximum current. Using Auriga’s advanced calibration algorithms and an external Keysight digital multimeter (DMM), Auriga MEM brings the DC measurement plane directly to the device under test.
Auriga 600V configuration
wdt_ID | Model | Description |
---|---|---|
1 | AU5 | Pulsed IV/RF Characterization System |
2 | PHG20 | Pulser Head, ±20 V, 100 mA, 2 W |
6 | PHG100 | Pulser Head, ±100 V, 2 A, 40 W |
7 | PHD600-5 | Pulser Head, 600 V, 5 A, 1000 W |
8 | N5752A | Power Supply to support 600 V Pulser Heads |
9 | AU5-RF (Optional) | Pulsed RF Option |
If you would like to customize your system further, Email us at info@focus-microwaves.com
Auriga PIV System - 1200 V Configuration
Auriga’s 5th generation pulsed IV/RF characterization system delivers unparalleled performance, capturing measurements with incredible speed and accuracy. Pulsed
IV (current-voltage) measurements have emerged as the preferred method of capturing current-voltage characteristics of active devices such as field effect (FETs) and bipolar junction (BJTs) transistors. With the growing popularity of higher-power devices, like GaN HEMTs, LDMOS, SiC, and graphene, current and voltage requirements are constantly being pushed higher and higher.
Auriga MEM™, Auriga’s newest pulsed IV function, enhances current resolution to an industry-leading 0.01% of maximum current. Using Auriga’s advanced calibration algorithms and an external Keysight digital multimeter (DMM), Auriga MEM brings the DC measurement plane directly to the device under test.
Auriga 1200V configuration
wdt_ID | Model | Description |
---|---|---|
1 | AU5 | Pulsed IV/RF Characterization System |
6 | PHG100 | Pulser Head, ±100 V, 2 A, 40 W |
7 | PHD1200-100 | Pulser Head, 1200 V, 100 A, 5000 W |
10 | PHD3000-HVK | High-Voltage filter kit for 1200 V Pulser Head series |
11 | AU-3R100-LCU | High Voltage Power Supply to support 1200 V Pulser Heads |
12 | AU5-RF (Optional) | Pulsed RF Option |
If you would like to customize your system further, Email us at info@focus-microwaves.com
Auriga PIV System - 2000 V Configuration
Auriga’s 5th generation pulsed IV/RF characterization system delivers unparalleled performance, capturing measurements with incredible speed and accuracy. Pulsed
IV (current-voltage) measurements have emerged as the preferred method of capturing current-voltage characteristics of active devices such as field effect (FETs) and bipolar junction (BJTs) transistors. With the growing popularity of higher-power devices, like GaN HEMTs, LDMOS, SiC, and graphene, current and voltage requirements are constantly being pushed higher and higher.
Auriga MEM™, Auriga’s newest pulsed IV function, enhances current resolution to an industry-leading 0.01% of maximum current. Using Auriga’s advanced calibration algorithms and an external Keysight digital multimeter (DMM), Auriga MEM brings the DC measurement plane directly to the device under test.
Auriga 2000V configuration
wdt_ID | Model | Description |
---|---|---|
1 | AU5 | Pulsed IV/RF Characterization System |
6 | PHG100 | Pulser Head, ±100 V, 2 A, 40 W |
7 | PHD2000-100 | Pulser Head, 2000 V, 100 A, 5000 W |
10 | PHD3000-HVK | High-Voltage filter kit for 2000 V Pulser Head series |
11 | AU-3R100-LCU | High Voltage Power Supply to support 2000 V Pulser Heads |
12 | AU5-RF (Optional) | Pulsed RF Option |
If you would like to customize your system further, Email us at info@focus-microwaves.com
REQUEST A QUOTE
Interested in Auriga AU5’s Pulsed IV system or want more information? Send us your name and email and we’ll respond in the same day.
REQUEST A QUOTE
Interested in Auriga AU5’s Pulsed IV system or want more information? Send us your name and email and we’ll respond in the same day.